 浏览型号EMC1414-A-AIA-TR的Datasheet PDF文件第27页浏览型号EMC1414-A-AIA-TR的Datasheet PDF文件第28页浏览型号EMC1414-A-AIA-TR的Datasheet PDF文件第29页浏览型号EMC1414-A-AIA-TR的Datasheet PDF文件第30页浏览型号EMC1414-A-AIA-TR的Datasheet PDF文件第32页浏览型号EMC1414-A-AIA-TR的Datasheet PDF文件第33页浏览型号EMC1414-A-AIA-TR的Datasheet PDF文件第34页浏览型号EMC1414-A-AIA-TR的Datasheet PDF文件第35页  
Multiple Channel 1°C Temperature Sensors with Beta Compensation
Datasheet
Bit 4 - RECD1 - Disables the Resistance Error Correction (REC) for External Diode 1.
‘0’ (default) - REC is enabled for External Diode 1.
‘1’ - REC is disabled for External Diode 1.
Bit 3 - RECD2 - Disables the Resistance Error Correction (REC) for External Diode 2 and External
Diode 3.
‘0’ (default) - REC is enabled for External Diode 2 and External Diode 3.
‘1’ - REC is disabled for External Diode 2 and External Diode 3.
Bit 2 - RANGE - Configures the measurement range and data format of the temperature channels.
‘0’ (default) - The temperature measurement range is 0°C to +127.875°C and the data format is
binary.
‘1’ -The temperature measurement range is -64°C to +191.875°C and the data format is offset
binary (see
Bit 1 - DAVG_DIS - Disables the dynamic averaging feature on all temperature channels.
‘0’ (default) - The dynamic averaging feature is enabled. All temperature channels will be converted
with an averaging factor that is based on the conversion rate as shown in
‘1’ - The dynamic averaging feature is disabled. All temperature channels will be converted with a
maximum averaging factor of 1x (equivalent to 11-bit conversion). For higher conversion rates, this
averaging factor will be reduced as shown in
Bit 0 - APDD (EMC1414 only) - Disables the anti-parallel diode operation. Beta Compensation is
disabled on External Diode 2 and 3 regardless of APDD setting. In addition, External Diode 2 Beta
Configuration register will be ignored.
‘0’ (default) - Anti-parallel diode mode is enabled. Two external diodes will be measured on the
DP2 and DN2 pins.
‘1’ - Anti-parallel diode mode is disabled. Only one external diode will be measured on the DP2
and DN2 pins.
7.5
Conversion Rate Register
Table 7.5 Conversion Rate Register
ADDR
R/W
REGISTER
B7
B6
B5
B4
B3
B2
B1
B0
DEFAULT
04h
R/W
0Ah
Conversion
Rate
-
-
-
-
CONV[3:0]
06h
(4/sec)
The Conversion Rate Register controls how often the temperature measurement channels are updated
and compared against the limits. This register is fully accessible at either address.
Bits 3-0 - CONV[3:0] - Determines the conversion rate as shown in
Table 7.6 Conversion Rate
CONV[3:0]
HEX
0h
1h
3
0
0
2
0
0
1
0
0
0
0
1
CONVERSIONS / SECOND
1 / 16
1/8
SMSC EMC1413 / EMC1414
31
Revision 1.41 (02-23-12)