XCR3256XL 256 Macrocell CPLD
R
140
120
100
Typical ICC (mA)
80
60
40
20
0
0
20
40
60
80
100
120
140
160
Frequency (MHz)
Figure 1:
XCR3256XL Typical I
CC
vs. Frequency at V
CC
= 3.3V, 25
°
C
Table 1:
Typical I
CC
vs. Frequency at V
CC
= 3.3V, 25
°
C
Frequency (MHz)
Typical I
CC
(mA)
0
0.02
1
0.91
10
8.87
20
17.7
40
34.8
60
51.5
80
68
100
84.2
120
100.1
140
116.6
DC Electrical Characteristics Over Recommended Operating Conditions
(1)
Symbol
V
OH
V
OL
I
IL
I
IH
I
CCSB
I
CC
Parameter
Output High voltage for 3.3V outputs
Output Low voltage for 3.3V outputs
Input leakage current
I/O High-Z leakage current
Standby current
Dynamic current
(2,3)
Test Conditions
I
OH
= –8 mA
I
OL
= 8 mA
V
IN
= GND or V
CC
V
IN
= GND or V
CC
V
CC
= 3.6V
f = 1 MHz
f = 50 MHz
C
IN
C
CLK
C
I/O
Input pin capacitance
(4)
Clock input capacitance
(4)
I/O pin capacitance
(4)
f = 1 MHz
f = 1 MHz
f = 1 MHz
Min.
2.4
-
–10
–10
-
-
-
-
5
-
Max.
-
0.4
10
10
100
2
60
8
12
10
Unit
V
V
m
A
m
A
m
A
mA
mA
pF
pF
pF
Notes:
1. See XPLA3 family data sheet (DS012) for recommended operating conditions.
2. See
Figure1 for typical values.
3. This parameter measured with a 16-bit, loadable up/down counter loaded into every logic block, with all outputs disabled and
unloaded. Inputs are tied to V
CC
or ground. This parameter guaranteed by design and characterization, not testing.
4. Typical values not tested.
2
1-800-255-7778
Preliminary Product Specification