X9313
Absolute Maximum Ratings
Temperature Under Bias . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Voltage on CS, INC, U/D, and
V
CC
with respect to V
SS
. . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
Voltage on V
H
, V
L
, V
W
with respect to V
SS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . -6V to +7V
ΔV
= |V
H
- V
L
|:
X9313Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4V
X9313W, X9313U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10V
Lead Temperature (soldering 10s) . . . . . . . . . . . . . . . . . . . . . +300°C
I
W
(10s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .±8.8mA
ESD Rating
Human Body Model (Per MIL-STD-883 Method 3015.7) . . . 2.0kV
Machine Model (Per EIAJ ED-4701 Method C-111) . . . . . . . .200V
Recommended Operating Conditions
Temperature:
Commercial. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C
Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Supply Voltage (VCC):
X9313 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5V ±10%
X9313-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3V to 5.5V
Max Wiper current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±4.4mA
Power rating:
R
TOTAL
≥
10kΩ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10mW
R
TOTAL
1kΩ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16mW
Pb-free reflow profile . . . . . . . . . . . . . . . . . . . . . . . . . .see link below
Pb-free PDIPs can be used for through hole wave solder processing
only. They are not intended for use in Reflow solder processing
applications
CAUTION: Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only; functional
operation of the device (at these or any other conditions above those listed in the operational sections of this specification) is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
Potentiometer Characteristics
Over recommended operating conditions unless otherwise stated.
LIMITS
SYMBOL
PARAMETER
End-to-end resistance tolerance
V
VH
V
VL
R
W
I
W
V
H
terminal voltage
V
L
terminal voltage
Wiper resistance
Wiper current
Noise (Note 5)
Resolution
Absolute linearity (Note 1)
Relative linearity (Note 2)
R
TOTAL
temperature coefficient (Note 5)
Ratiometric temperature coefficient
(Note 5)
C
H
/C
L
/C
W
(Note 5)
NOTES:
1. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage = (V
W(n)(actual)
- V
W(n)(expected)
) = ±1 MI maximum.
2. Relative linearity is a measure of the error in step size between taps = R
W(n+1)
- (R
W(n)
+ MI) = ±0.2 MI.
3. 1 MI = minimum increment = R
TOT
/31.
Potentiometer capacitances
See Circuit #3
R
W(n)(actual)
- R
W(n)(expected)
R
W(n+1)
- (R
W(n)
+MI)
±300
±20
10/10/25
Ref: 1kHz
-120
3
±1
±0.2
I
W
= (V
H
- V
L
)/R
TOTAL
, V
CC
= 5V
-
V
CC
-
V
CC
40
TEST CONDITIONS/NOTES
MIN
TYP
MAX
±20
+
V
CC
+
V
CC
100
±4.4
UNIT
%
V
V
Ω
mA
dBV
%
MI
(Note 3)
MI
(Note 3)
ppm/°C
ppm/°C
pF
5
FN8177.5