Large, Easy-to-Read Displays: Clear Even from a Distance  
Industry's First Power Tuning Function in a Digital Sensor.  
Large, bright  
Patent Pending  
No complicated mode settings.  
operation indicator  
Troublesome power adjustments have been eliminated, so it isn't necessary  
to select from power mode settings, such as long-distance mode, standard  
mode, and short-distance mode. When the MODE Key is pressed once, the  
power tuning function shifts the power level so that the present incident level  
is set to the ideal level (2000 on the digital display.)  
(like earlier models)  
The displays are large and easy-to-read,  
despite the small case.  
Incident level  
Threshold level  
RUN mode  
Incident level Threshold level  
Earlier Method  
New Method  
Industry's largest  
characters: 6 mm  
(like earlier models)  
Incident  
Settings can be made more simply and confident-  
High-speed mode  
Power tuning indicator added  
to indicate setting status.  
insufficient  
Up to 5-fold increase Press  
ly with two digital displays. For example, the  
threshold value can be changed while reading the  
incident level or a setting can be changed while  
confirming the setting's function item number.  
No power modes  
Short-distance mode  
Standard mode  
Appropriate  
Appropriate  
Function  
Setting  
Up to 1/25 reduction  
SET mode  
Long-distance mode  
Saturated  
Saturated  
The Sensor can be used immediately without  
setting the mode.  
Function numbers  
added to function  
items.  
Super-long-distance mode  
If the incident light level is too high or too low,  
just press the Mode key to achieve the optimum  
status.  
The best mode for each application was  
selected from several power modes.  
Settings are now reversible.  
Insufficient light or saturation at short distances can be corrected.  
The power tuning range is extended to the allowable limits to eliminate prob-  
lems such as insufficient light or detection failures due to saturation.  
If the installation distance is too short, the incident light may saturate (i.e., to  
a digital incident level of 4,000), preventing detection. The power can be  
tuned down to 1/25th of the default setting for stable detection even at close  
range.  
Patent Pending  
Seven Convenient Display Formats  
Press  
An incident level/threshold display, percentage/threshold display, and large bar graph display  
have been added, so you can select the best display method for the application.  
Without workpiece  
Incident level  
Large Bar Graph Display  
Percentage/Threshold Display  
Incident Level/Threshold Display  
Incident level changes.  
does not change.  
Transparent workpiece  
Incident light  
No incident light  
Incident level  
Threshold level  
Incident level  
Threshold level  
Detection is not possible  
Bar display  
Detection is possible.  
With workpiece  
Change the threshold level while read-  
ing the incident level.  
Verify the difference between the inci-  
dent level and threshold level while set-  
ting the threshold level.  
Check the incident level intuitively. Ideal  
when it is better to view an analog dis-  
play instead of the actual digital level.  
Variations between different Sensors can be eliminated.  
Threshold levels had to be set and maintained separately for individual Sen-  
sors due to variations in the digital light levels measured by each Sensor.  
With power tuning, the incident level can be fine-tuned so the same thresh-  
old level can be set for each Sensor in an application. Maintenance is also  
simplified because it is easier to recognize measurement levels that have  
shifted during operation.  
Incident Level/Peak Hold Display  
Peak Hold/Bottom Hold Display  
2055  
2010  
Press  
Incident level  
Peak hold  
Earlier Method  
New Method  
Threshold  
level  
1350  
1280  
Simultaneously display the peak hold level and  
present incident level. The optical axis can be  
adjusted more easily and surely by checking the  
peak hold level while adjusting the optical axis.  
Display the peak level when light was brightest and bottom level when light was  
dimmest. The digital levels of high-speed objects can be read precisely.  
(Refreshing the hold level was changed from a fixed time to synchronizing with  
the output, so the peak and bottom hold values can be checked with certainty.)  
Detecting missing tablets  
Digital light levels vary due to individual  
differences in the Sensors, so the  
threshold levels must be set individually.  
All of the Amplifiers are set to the same digi-  
tal light level, so the same threshold level  
can be set and maintained for the Sensors.  