Stable, Long-term Performance with OMRON's APC Function  
Many Advanced Functions for Even More Applications  
Fastest in the Industry  
Detecting Leads on Electronic Parts  
Highest Level of Stability  
OMRON provides the industry's most stable long-term detection  
by using new 4-element LEDs and an APC (Auto Power Control) circuit.  
Provides high-speed response for miniature workpieces, such as chip parts and devices with short tact times.  
In addition to our unique APC circuit used in the  
Earlier Method  
New Method  
Three kinds of timer functions are supported. The timers can be set between 1 ms and 5 s.  
A one-shot timer is supported in addition to the ON-delay and OFF-delay timers.  
The Amplifier's ON time can be fixed, which is useful during high-speed workpiece detection.  
E3X-DA-N Amplifiers to compensate for the dete-  
rioration of the LED, the E3X-DA-S uses 4-ele-  
ment LEDs to counteract the deterioration of the  
light-emitting elements over time and achieve the  
industry's most stable long-term detection perfor-  
mance.  
3-element LED and APC  
4-element LED and APC  
Long-term stability  
Furthermore, the circuit is designed with excess  
light capacity, so the Sensors can be used with  
high stability regardless of whether the APC cir-  
cuit is ON or OFF.  
Discriminating Tablet Lengths  
Area output  
Area output function can be  
used for range judgement.  
(Advanced Twin-output Models)  
Without APC circuit  
Without APC circuit  
Incident  
level  
Time  
Time  
2000  
1000  
Threshold 1  
Threshold 2  
Operations that required multiple Sensors, such as  
height measurement, can be performed with just one  
Sensor. Two threshold levels can be set to easily output  
within-range and out-of-range outputs.  
Compensate for the effects of contaminants and temperature variation  
with differential operation mode. (Advanced Models)  
Time  
Output  
ON  
OFF  
This operation mode uses a special OMRON algorithm to compensate for slight light level changes  
due to dirt or temperature variations and detect only the light level changes due to the workpiece.  
Detecting Seals  
Slight light level changes can be detected with stability and  
precision, eliminating the need for time-consuming manual ad-  
justments for light level changes.  
Remote input function can control the Sensor remotely.  
(Advanced External-input Models)  
Input signals can make various remote settings, such as teaching operations, power tuning, and emitter  
OFF. This model is ideal for diverse needs, such as checking Sensor operation remotely before operation  
or making settings remotely because teaching has to be performed often for frequent workpiece model  
changes.  
Detecting marks in a dusty environment  
With the Twin-output Amplifiers, output 2 can function as an  
alarm output (light level operation) to indicate when the light  
level has changed due to dirt or other causes.  
Patent Pending  
Light Level Operation  
Patent Pending  
The counter function can output signal after counter  
(Normal Operation)  
Differential Operation  
counts up or down.  
Counter Function  
Judges light level changes by comparing  
the incident level and threshold level.  
Judges light level changes by comparing the  
incident level to a time-averaged incident level.  
Detecting Chip Components  
(Advanced External-input Models)  
Up Counter  
Down Counter  
Incident  
level  
Incident  
level  
A counter function is built-in, so the number  
of workpieces can be counted without a sep-  
arate counter or small PLC that used to be  
required.  
Threshold  
level  
Alarm output  
Detecting knots in thread  
Time  
Time  
Time  
Threshold level  
(absolute value)  
Counter  
Counter  
Counter  
value  
Alarm output  
Incorrect operation due to light level change  
Light level difference  
threshold  
(absolute value)  
Time  
Time  
Time  
The light level varies due to dirt, temperature  
variations, or other environmental factors.  
Detecting differences in the light level enables  
setting more subtle light level differences.  
Incorrect operation  
Minute changes are  
detected reliably.  
Output when count reaches SV.  
Output when count reaches 0.  
6