欢迎访问ic37.com |
会员登录 免费注册
发布采购

E3X-DA44V 参数 Datasheet PDF下载

E3X-DA44V图片预览
型号: E3X-DA44V
PDF下载: 下载PDF文件 查看货源
内容描述: 终极光纤放大器为方便用户使用和高性能的 [The Ultimate Fiber Amplifier for Maximum Ease of Use and High Performance]
分类和应用: 模拟IC光纤信号电路光纤放大器
文件页数/大小: 36 页 / 1425 K
品牌: OMRON [ OMRON ELECTRONICS LLC ]
 浏览型号E3X-DA44V的Datasheet PDF文件第4页浏览型号E3X-DA44V的Datasheet PDF文件第5页浏览型号E3X-DA44V的Datasheet PDF文件第6页浏览型号E3X-DA44V的Datasheet PDF文件第7页浏览型号E3X-DA44V的Datasheet PDF文件第9页浏览型号E3X-DA44V的Datasheet PDF文件第10页浏览型号E3X-DA44V的Datasheet PDF文件第11页浏览型号E3X-DA44V的Datasheet PDF文件第12页  
E3X-DA-N
Digital Fiber Amplifiers with Differential Outputs (E3X-DA11D/E3X-DA6D)
Characteristics of Applicable Fiber Units
Through-beam Fiber Units
Sensing distance (mm) (The figures in parentheses apply when using the 39-F1 Lens Unit.)
Sensitivity selection
11-level setting
Response
time
1
270 or
570
μs
240 (1680)
50
580
380
HIGH
2
0.5 or 1 ms
280 (1960)
60
690
450
3 to 11
1 to 200 ms
or
2 to 400 ms
370 (2590)
80
910
600
1
270 or
570
μs
140 (980)
30
350
230
LOW
2
0.5 or 1 ms
180 (1260)
40
450
290
3 to 11
1 to 200 ms
or
2 to 400 ms
240 (1680)
50
580
380
(0.3 dia.)
*1
(0.2 dia.)
*2
Standard object
(mm)
*1
(min. sensing
object
*2:
opaque)
Fiber Unit
E32-T11R
E32-T21R
E32-T16WR
E32-T16PR
1 dia. (0.01 dia.)
*1. These values are for sensing objects that are moving.
*2. This value applies when the response time is set to 3 to 11. An object of this value is detectable if the temperature changes within the range of ambient operating
temperature. (The value is for sensing objects that are moving.)
*3. The values given in the above table are those that can be detected at a digital value of 1,000 in each sensing area.
Reflective Fiber Units
Sensing distance (mm)
*1
Sensitivity selection
11-level setting
Response
time
1
270 or
570
μs
80
13
HIGH
2
0.5 or 1 ms
3-11
1 to 200 ms
or
2 to 400 ms
120
20
1
270 or
570
μs
45
7
LOW
2
0.5 or 1 ms
3-11
1 to 200 ms
or
2 to 400 ms
80
13
Standard object
(mm)
*2
(min. sensing
object
*3:
opaque)
150
×
150
(0.01 dia.)
25
×
25 (0.01 dia.)
Fiber Unit
E32-D11R
E32-D21R
90
15
60
10
*1. Sensing distances are given for white paper.
*2. These values are for sensing objects that are moving.
*3. This value applies when the response time is set to 3 to 11. An object of this value is detectable if the temperature changes within the range of ambient operating
temperature. (The value is for sensing objects that are moving.)
Differences Compared with E3X-DA-N Amplifier
Differential-output Models (Edge-detection Models)
Type
Item
Con-
trol
output
NPN output
Current consumption
ON/OFF output
Pre-wired
E3X-DA11D
Wire-saving connector
E3X-DA6D
960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC)
Load current: 50 mA max., (Residual voltage: 1 V max. for NPN/PNP output)
Open collector
Switchable between Light ON (ON at edge detection) and Dark ON (OFF at edge detection)
Switchable between single edge and double edge detection mode
Single edge: Can be set to 270
μs,
500
μs,
1 ms, 2 ms, 4 ms, 10 ms, 20 ms, 30 ms, 50 ms, 100 ms, or 200 ms.
Double edge: Can be set to 570
μs,
1 ms, 2 ms, 4 ms, 10 ms, 20 ms, 30 ms, 50 ms, 100 ms, 200 ms or 400 ms.
Light ON: OFF-delay timer, Dark ON: ON-delay timer
0 to 5 s (1 to 20 ms: 1-ms units, 20 to 200 ms: 5-ms units, 200 ms to 1 s: 100 ms, 1 to 5 s: 1-s units)
Yes
Yes (Negative values can be displayed.)
Yes (Settings can be returned to defaults.)
Yes (HIGH/LOW)
One-point teaching level can be varied from 1% to 50% in increments of 1%
Operation indicator (orange), 7-segment digital incident level display (red), 7-segment digital detection level display
(red)
Detection mode
Response time
Timer functions
APC
Func-
tions
Zero-reset
Initial reset
Sensitivity se-
lection
Teaching level
Indicators
For other information, refer to the instruction manual supplied with the product.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
8