XCR3032XL 32 Macrocell CPLD
R
DC Electrical Characteristics Over Recommended Operating Conditions
(1)
Symbol
V
OH(2)
Parameter
Output High voltage
Test Conditions
V
CC
= 3.0V to 3.6V, I
OH
= –8 mA
V
CC
= 2.7V to 3.0V, I
OH
= –8 mA
I
OH
= –500
µA
V
OL
I
IL(4)
I
IH(4)
I
CCSB
I
CC
C
IN
C
CLK
C
I/O
Output Low voltage
Input leakage current
I/O High-Z leakage current
Standby current
Dynamic current
Input pin capacitance
Clock input capacitance
I/O pin capacitance
I
OL
= 8 mA
V
IN
= GND or V
CC
V
IN
= GND or V
CC
V
CC
= 3.6V
f = 1 MHz
f = 50 MHz
f = 1 MHz
f = 1 MHz
f = 1 MHz
Min.
2.4
2.0
90% V
CC
-
–10
–10
-
-
-
-
-
-
Max.
-
-
-
0.4
10
10
100
0.25
7.5
8
12
10
Unit
V
V
V
V
µA
µA
µA
mA
mA
pF
pF
pF
Notes:
1. See XPLA3 family data sheet (
) for recommended operating conditions
2. See
for output drive characteristics of the XPLA3 family.
3. This parameter guaranteed by design and characterization, not by testing.
4. Typical leakage current is less than 1
µA.
5. See
Table 1, Figure 1
for typical values.
6. This parameter measured with a 16-bit, resetable up/down counter loaded into every function block, with all outputs disabled and
unloaded. Inputs are tied to V
CC
or ground. This parameter guaranteed by design and characterization, not testing.
7. Typical values, not tested.
100
90
80
70
60
I
OL
(3.3V)
mA
50
40
30
20
10
0
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
I
OH
(2.7V)
I
OH
(3.3V)
Volts
DS012_10_031802
Figure 2:
Typical I/V Curve for the XPLA3 Family, 3.3V, 25°C
2
1-800-255-7778
DS023 (v1.6) June 27, 2002
Preliminary Product Specification