G5V-2
G5V-2
High Sensitivity Models
Rated voltage
3 VDC
50 mA
60
5 VDC
30 mA
166.7
0.46
6 VDC
25 mA
240
9 VDC
16.7 mA
540
12 VDC
12.5 mA
960
24 VDC
8.33 mA
2,880
6.72
48 VDC
Rated current
6.25 mA
7,680
20.1
Coil resistance
Coil inductance Armature ON
0.18
0.70
1.67
2.90
(H) (ref. value)
Armature OFF 0.57
0.71
0.97
2.33
3.99
9.27
26.7
Must operate voltage
Must release voltage
Max. voltage
75% max. of rated voltage
5% min. of rated voltage
180% of rated voltage at 23°C
150% of rated
voltage at
23°C
Power consumption
Approx. 150 mW
Approx.
200 mW
Approx.
300 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
I Contact Ratings
Item
Standard models
Resistive load (cos = 1)
High sensitivity models
Load
Rated load
0.5 A at 125 VAC; 2 A at 30 VDC
Ag + Au-clad
0.5 A at 125 VAC; 1 A at 24 VDC
Contact material
Rated carry current
2 A
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value)
125 VAC, 125 VDC
2 A
1 A
62.5 VA, 60 W
0.01 mA at 10 mVDC
62.5 VA, 24 W
–6
Note Note:P level: l60 = 0.1 x 10 /operation
I Characteristics
Item
Standard models
High sensitivity models
Contact resistance
Operate time
50 m max.
100 m max.
7 ms max.
3 ms max.
Release time
Bounce time
Operate: approx. 0.3 ms
Release: approx. 1.5 ms
Max. operating frequency
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance
Dielectric strength
1,000 M min. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between con-
tacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between coil
and contacts
1,000 VAC, 50/60 Hz for 1 min between con-
tacts of different polarity
750 VAC, 50/60 Hz for 1 min between contacts 500 VAC, 50/60 Hz for 1 min between contacts
of same polarity of same polarity
Impulse withstand voltage
Vibration resistance
1,500 V (10 x 160 µs) between coil and contacts (conforms to FCC Part 68)
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
2
2
Shock resistance
Endurance
Destruction: 1,000 m/s (approx. 100G)
Destruction: 1,000 m/s (approx. 100G)
2
2
Malfunction: 200 m/s (approx. 20G)
Malfunction: 100 m/s (approx. 10G)
Mechanical: 15,000,000 operations min. (at 36,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr)
Ambient temperature
Ambient humidity
Weight
Operating: 25°C to 65°C (with no icing)
Operating: 5% to 85%
Operating: 25°C to 70°C (with no icing)
Approx. 5 g
2