IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (OPTION 060 ONLY)
Characteristic
8 Pin DIP
Description
Symbol
SO-8
Units
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤300 V rms
I-IV
I-III
I-III
for rated mains voltage ≤450 V rms
Climatic Classification
55/100/21
2
55/100/21
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
2
V
630
560
V peak
V peak
IORM
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial Discharge < 5 pC
VPR
VPR
1181
945
1050
840
Input to Output Test Voltage, Method a*
V
x 1.5 = VPR, Type and sample test,
V peak
tmIO=RM60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
VIOTM
6000
4000
V peak
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 9, Thermal Derating curve.)
Case Temperature
Input Current
Output Power
TS
IS,INPUT
PS,OUTPUT
175
230
600
175
150
600
°C
mA
mW
Insulation Resistance at TS, VIO = 500 V
RS
≥ 109
≥ 109
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (HCNW135/6 ONLY)
Description
Symbol
Characteristic
Units
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤600 V rms
I-IV
I-III
for rated mains voltage ≤1000 V rms
Climatic Classification
55/85/21
2
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
V
1414
V peak
V peak
IORM
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial Discharge < 5 pC
VPR
VPR
2652
2121
8000
Input to Output Test Voltage, Method a*
V
x 1.5 = VPR, Type and sample test,
V peak
tmIO=RM60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
VIOTM
V peak
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Figure 9, Thermal Derating curve.)
Case Temperature
Input Current
Output Power
TS
IS,INPUT
PS,OUTPUT
150
400
700
°C
mA
mW
Insulation Resistance at TS, VIO = 500 V
RS
≥ 109
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-2, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
8