InfraSpec VFA-IR光谱仪

日期:2016-8-15类别:会员资讯 阅读:135 (来源:互联网)
公司:
商斯达(香港深圳北京上海西安)有限公司
联系人:
销售部(香港深圳北京上海西安成都武汉等设分公司特价连锁经营)
手机:
13823676822微信同号
电话:
0755-83376489 83778810 83600718
传真:
0755-83376182
QQ:
583757894 1295084882
地址:
深圳市福田福华路鸿图大厦1602室、2005-2006室;:上海市北京东路668号上海賽格电子市场 : 西安高新开发区20所(导航技术研究所)
摘要:InfraSpec VFA-IR光谱仪

InfraSpec VFA-IR光谱仪

 


供应InfraSpec VFA-IR光谱仪,是一款基于可变滤波片阵列技术的中红外光谱仪(VFA-IR Spectrometer)。该系列InfraSpec VFA-IR中红外光谱仪具有如下特点:采集速度快(<60s)、坚实耐用(无移动部件)、光路不暴露、结构紧凑,广泛应用于液体、浆体、半固态、薄膜等材料的中红外光谱检测,包括:生物燃料分析、生物柴油/食用油中的脂肪酸检测、饮料中的酒精检测、薄膜分析、D2O in H2O或H2O in D2O。

  
InfraSpec VFA-IR Spectrometer
Specifications
Power Requirements
12V DC 2.0A
Power Supply
Universal AC/DC
Weight
1.5kg
Dimensions
152×165×70mm³
Suggested Operating Range
5-40°C
Humidity
0-98% relative humidity
Dector Array
128 pixel linear pyroelectric array
Array Responsivity
5.4-105V/W
Standard Spectral Range
5.4-10.8µm
Resolution
25cm-1
Typical Measurement Range for Ethanol
0-98% Ethanol in Gasoline
Typical Measurement Range for Biodiesel
0-100% Biodiesel in Diesel
Analysis Time
Less than one minute
Instrument Repeatability
0-20%±0.2%, 20-100%±1% of concentration
Communication Port
RS232 and USB
ATR Crystal
Zinc Selenide
ATR Surface Size
50mm×16mm
Part Number
405-2017-1013
InfraSpec VFA-IR Spectrometer, Model E for Biofuel measurements. Complete with 5.4-10.8µm spectral range, 128 pixel array, trough plate with ZnSe ATR Crystal, Igor pro software, Power supply, USB cable and Instruction manual.
405-2026-1013
InfraSpec VFA-IR Spectrometer, Model ES with Stainless Steel Sample Plate Cover for Biofuel measurements. Complete with 5.4-10.8µm spectral range, 128 pixel array, trough plate with ZnSe ATR Crystal, Igor pro software, Power supply, USB cable and Instruction manual.
405-2017-1020
InfraSpec VFA-IR Spectrometer, Model EB specifically designed for measuring low level Biodiesel in diesel. Complete 2mm amalgamated flow through cell transmission, 5.4-10.8µm spectral range, Igor pro software, Power supply, USB cable and Instruction manual. Note:  The 10ml Glass Luer-Lok Syringe not included, is necessary for introducing the sample into the sample holder.
Accessories
400-1020
RS 223 Cable
403-0013
Carrying case for InfraSpec Analyzers with pre-diced pluck foam
403-1055
Carrying case for InfraSpec Analyzer, Model EB with pre-diced pluck foam
205-1115
10ml Glass Luer-Lok Syringe
Replacement Parts
313-1012
Replacement Source for InfraSpec VFA-IR Spectrometer

Wilks油脂分析仪

 
  
InfraCal 4 character LED      InfraCal 2 Touch screen New

供应Wilks油脂分析仪,是一种简便而准确的红外在线分析方法,用于检测:水中的油(TOG, Total Oil and Grease)、土壤中的石油烃(TPH, Total Petroleum Hydrocarbons)、废水中的油脂(FOG, Fats, Oil and Grease)。该系列TOG/TPH油脂分析仪FOG/TOG油脂分析仪具有如下特点:检测速度快(10-15分钟)、检测范围宽(0.1ppm-5000ppm 脂肪烃和芳香烃)、结构紧凑(165×165×127mm³, 2.2kg)、检测标准严格(ASTM D7066和EPA 166),目前在全球范围超过3000套的使用量,已经成为油脂检测和监控的行业标准。依据检测灵敏度和提取溶剂的区别,如下型号可供选择:InfraCal Model HATR-T2、InfraCal Model CVH、InfraCal Model CH、InfraCal 2 Model ATR-SP、InfraCal 2 Model TRANS-SP。

  
Model
InfraCal 
Model HATR-T2
InfraCal 
Model CVH
InfraCal 2 
Model ATR-SP
InfraCal 2 
Mode TRANS-SP
Technology
3.4μm fixed filter infrared analyzer
Min detection Water
8 ppm
2 ppm
0.3 ppm
0.1 ppm
Min detection Soil
40 ppm
10 ppm
3 ppm
1 ppm
Solvent
Hexane, Pentane, Cyclohexane, Vertrel MCA
Perchloroethylene, 
S-316, Freon-113
Hexane, Pentane, Cyclohexane, Vertrel MCA
Perchloroethylene, 
S-316, Freon-113
Components measured
Hydrocarbons with boiling point higher than solvent
All hydrocarbons
Hydrocarbons with boiling point higher than solvent
All hydrocarbons
Method complies
N.A.
ASTM D7066, 
EPA 413.2, EPA 418.1
N.A.
ASTM D7066, 
EPA 413.2, EPA 418.1
Method compares
EPA 1664, ISO 9377-2
EPA 1664, ISO 9377-2
EPA 1664, ISO 9377-2
EPA 1664, ISO 9377-2
Volatile componets
Loses
Includes
Loses
Includes
Data acquisition
Printer from Wilks
Printer from Wilks
Internal data 
storage & export
Internal data 
storage & export
Calibrations
Single
Single
Multiple
Multiple
Display
4 character LED
4 character LED
Touch screen
Touch screen
Password protection
No
No
Yes
Yes
Battery pack
External
External
Internal
Internal
Others
Solvents lighter than water, sample collected form container top
Solvents heavier than water, requires separatory funnel or septa cap vial
Solvents lighter than water, sample collected form container top
Solvents heavier than water, requires separatory funnel or septa cap vial

  
Model
P/N
Description
Min Detection 8 ppm
405-1009
Includes 100 mrcroliter sypringe, Un-calibrated
InfraCal 
Model HATR-T2
405-1009-44
Factory calibrated using 403-1044
403-1044
TOG/TPH calibration standard set
405-1009-72
Factory calibrated using 403-1072
403-1072
FOG/TOG calibration standard set
403-1067
InfraLog serial printer
403-0013
Carrying case
403-0003
External 12V battery pack
403-0002
12V automotive power adapter cable
403-0005
Dust cover
403-1011
Field sampling kit
Min Detection 2 ppm
405-0003/12
Includes set of 4-10mm cuvettes, Un-calibrated
InfraCal 
Model CVH
405-0003/12-41
Factory calibrated using 403-1041
403-1041
S-316 TOG/TPH calibration standard set
405-0003/12-40
Factory calibrated using 403-1040
403-1040
S-316 FOG/TOG calibration standard set
405-0003/12-64
  
405-0003/12-78
Factory calibrated using 403-1064
403-1064
Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration standard set
403-0012
Set of 4-10mm quartz cuvette cells
403-1067
InfraLog serial printer
403-0013
Carrying case
403-0003
External 12V battery pack
403-0002
12V automotive power adapter cable
403-0005
Dust cover
403-1063
Field sampling kit
Min Detection 0.3 ppm
405-2034
Includes set of 4-10mm cuvettes, Un-calibrated
InfraCal 2 
Model ATR-SP
405-2034-81
Factory calibrated using 403-1081
403-1081
Hexane TOG/TPH calibration standard set (Low range)
405-2034-44
Factory calibrated using 403-1044
403-1044
Hexane TOG/TPH calibration standard set (High range)
405-2034-8144
Factory calibrated using 403-1081 and 403-1044
405-2034-72
Factory calibrated using 403-1072
403-1072
Hexane FOG/TOG calibration standard set
403-0013
Carrying case
403-1011
Field sampling kit
Min Detection 0.1 ppm
405-2035
Includes set of 4-10mm cuvettes, Un-calibrated
InfraCal 2 
Model TRANS-SP
405-2035-80
Factory calibrated using 403-1080
403-1080
S-316 TOG/TPH calibration standard set (Low range)
405-2035-41
Factory calibrated using 403-1041
403-1041
S-316 TOG/TPH calibration standard set (High range)
405-2035-8041
Factory calibrated using 403-1080 and 403-1041
405-2035-40
Factory calibrated using 403-1040
403-1040
S-316 FOG/TOG calibration standard set
405-2035-79
Factory calibrated using 403-1079
403-1079
Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration standard set (Low range)
405-2035-78
Factory calibrated using 403-1078
403-1078
Tetrachloroethylene (Perchloroethylene) TOG/TPH calibration standard set (High range)
405-2035-7978
Factory calibrated using 403-1079 and 403-1078
403-0012
Set of 4-10mm quartz cuvette cells
403-0013
Carrying case
403-1063
Field sampling kit
403-1083
Field sampling kit for sub-ppm

Wilks生物燃料分析仪

 


供应生物燃料分析仪,包括:生物柴油分析仪、乙醇分析仪、VFA-IR光谱仪。该系列Biofuel Analyzers生物燃料分析仪具有便携式、操作简单、坚固耐用的特点,广泛应用于:柴油中生物柴油检测、汽油中乙醇检测、乙醇中水检测。

  
Specifications
InfraSpec VFA-IR Spectrometer, Model E
InfraSpec VFA-IR Spectrometer, Model ES
InfraSpec VFA-IR Spectrometer, Model EB
InfraCal Biodiesel Blend Analyzer
InfraCal 
Ethanol Blend Analyzer
Biodiesel in Diesel
YES
YES
NO
YES
NO
Ethanol in Gas/Petrol
NO
YES
NO
NO
YES
Low Level Biodiesel Detection
NO
NO
YES
NO
NO
FFA in Feedstock
YES
YES
NO
NO
NO
Water in Feedstock
YES
YES
NO
NO
NO
Water in Ethanol or Methanol
YES
YES
NO
NO
NO
Total Glyceride for Production
YES
YES
NO
NO
NO
Applications
Non-volatile samples
Volatile samples, and a sample plate cover to reduce evaporation 
Detect ppm levels of biodiesel in diesel
Direct readout in % biodiesel (FAME) in diesel
Ethanol in petrol/gasoline analysis

InfraRan气体分析仪

 


供应InfraRan气体分析仪(InfraRan Specific Vapor Analyzer),是一种单光束红外气体分析仪,用于现场实时测量单一气体或多种气体的浓度(2.5-14µm光谱波段范围内有特征吸收光谱的气体或气体混合物)。该系列气体分析仪具有如下特点:响应速度快、检测精度高、维护率低、简便轻便,因此广泛应用于各类气体的检测,包括:丙酮、二氧化碳、一氧化碳、己烷、一氧化氮、四氯乙烯、甲苯、SF6、R 114、R 12、R 134A、R 236 fa。

  
InfraRan Specific Vapor Analyzer
Specifications
Power requirement
120-220VAC - 50/60Hz 
Battery pack rechargeable
12V 9 Ah capacity
Dimensions
381×185×191mm³
Weight
8.2kg
Enclosure
High impact Polymer
Type
Single Beam Infrared Spectrophotometer
Optics
Cell 1st Surface Gold & Pyrex Photometer, Fixed Band Pass Filters (specific to the gas or gases to be measured)
Cell pathlength
6.0 meter is used for most gases - for a high concentration range of a specified gas or gases, a 1.2m or 16cm cell may be used
Sample cell volume
0.45L
Sample flow
10L per min
Gas purge 
5 Cell volumes for 99% purge of cell (approx. 5 sec @ 10 liters/min) 
Measurement cycle 
Display updated every second 
Source 
Thin film on diamond-like carbon support 
Communications
USB and RS232 for connection with PC
Concentration alarm
High & Low (selectable by user) 
Display
Vacuum fluorescent - 8 Lines × 40 Characters plasma display
Key pad
20 key tactile Keypad
Part Number
405-2000-1017 
InfraRan SF6 Single-Gas Analyzer Single-beam infrared spectrophotometer with fixed wavelength filter/detector for measuring sulfur hexafluoride (SF6) in the 0-10 ppm concentration range with 0.01 ppm detection limit. Includes menu-driven software and factory calibration for SF6, internal battery pack with external charger and power supply (85-250VAC, 50-60Hz, universal input), RS232 and USB communication ports, sampling wand, two charcoal zero filters, shoulder strap and instruction manual.Ideal for determining Chemical Fume Hood (ASHRAE 110) or Room Flow Rate Efficiencies.
405-2000-XXXX 
Note: Last four digits indicate 
Gas Calibration Code
InfraRan Single-Gas Specific Vapor Analyzer Single beam infrared photometer with fixed wavelength filter/detector for measuring specified gas and concentration range (see table below). Includes menu-driven software and factory calibration for specified gas, internal battery pack with external charger and power supply (85-250VAC, 50-60Hz, universal input), RS232 and USB communication ports, sampling wand, two charcoal zero filters, shoulder strap and instruction manual.
405-2004
4-Gas Refrigerant Specific Vapor Analyzer Single beam infrared Spectrophotometer with fixed wavelength/detector for measuring R114, R134a, R236a, and Halon 13B1 in the 0-2500 ppm concentration range. Includes menu-driven software and factory calibration for R114, R134a, R236a, and Halon 13B1, internal battery pack with external charger and power supply (85-250VAC, 50-60Hz, universal input), RS232 and USB communications ports, sampling wand, two charcoal zero filters, shoulder strap and instruction manual.
405-2005-0001
4-Gas Anesthetic Specific Vapor Analyzer for measuring anesthetic gases individually Single beam infrared spectrophotometer with four-wavelength filter/detector for measuring Nitrous Oxide (0-100 ppm), Desflurane (0-50ppm), Isoflurane (0-50ppm) and Sevoflurane (0-50ppm). Includes menu-driven software and factory calibration for the above anesthetic gases, internal battery pack with external charger and power supply (85-250VAC, 50-60Hz, universal input), RS232 and USB communications ports, sampling wand, two charcoal zero filters, shoulder strap and instruction manual.
 Accessories
403-1015
Travel Case for InfraRan Analyzer with diced foam, reinforced extendable handle, large 3 inch wheels, stainless steel twist-lock latches and spring loaded steel handles.
 403-1019
Analog Output for InfraRan Analyzer  This option should be specified and ordered with the purchase of the InfraRan Analyzer.  Included as standard with P/N 405-2000-1017 InfraRan SF6 Single-Gas Analyzer.
500-0022
R515A Charcoal Zero Filter, 2 pack Particulate Filter 
205-1029
Particulate Filter
Replacement Parts
212-0001 
Replacement 12V NiMH Battery Pack
405-1022
Replacement Sampling Wand Assembly with flexible hose and particulate filter.
405-2024 
Battery Charger Assembly including battery charger, power cord with ferrite and connecting cable for connecting the InfraRan Analyzer to the battery charger.
405-2027 
Zero Filter Holder
211-0004 
Shoulder Strap

  
 Standard Gases
Gas 
Calibration Code
Gas Compound
Concentration Range Limit (ppm)
Wavelength
(µm)
Detection Limit
(ppm)
Cell Pathlength 
1001
Acetone
0-1000
8.2
5
long
1002
Carbon Dioxide (CO2)
0-3000
4.25
3
short
1003
Carbon Monoxide (CO)
0-100
4.61
1
long
1004
Carbon Tetrachloride
0-25
12.6
0.1
long
1005
Desflurane
0-50
8.5
0.1
long
1006
General Hydrocarbons (Hexane)
0-500
3.33
0.5
long
1007
Isoflurane
0-50
8.8
0.1
long
1008
Isopropyl Alcohol (IPA)
0-500
8.8
2
long
1009
Methylene Chloride
0-100
13.2
2
long
1010
Nitrous Oxide
0-100
4.5
0.1
long
1011
Perchloroethylene
0-50
10.9
0.1
long
1012
R 114
0-2000
8.38
10
short
1013
R 12
0-2000
9.1
10
short
1014
R 134A
0-2000
8.05
10
short
1015
R 236 fa
0-2000
8.38
10
short
1016
Sevoflurane
0-50
8.05
0.1
long
1017
Sulfur Hexaflouride (SF6)
0-5
10.68
0.01
long
1018
Toluene
0-200
13.8
1
long
Notes: Other gases, ranges and wavelengths are available upon requests.

InfraCal Soot Meter烟尘仪

 


供应美国Wilks公司的InfraCal Soot Meter烟尘仪,是一种ASTM 7686-11认可的用于测量柴油发动机润滑油的碳(煤烟)含量的测量方法。该系列烟尘分析仪具有如下特点:使用方便,检测速度快、测量范围大、无需样品制备和稀释过程,广泛用于润滑剂的评估和筛选,应用场所包括:油品检测实验室、发动机测试实验室、车站维修点、建筑或采矿点、航船、发电站。

  
InfraCal Soot Meter
Model HATR-CP
Analytical Wavelength
3.9µm, 2553cm-1
Sample Surface
Cubic Zirconia ATR Crystal
Scratch resistant, impervious to acids
Display 
4 digit, 7-segment red LED, 5/8 in. character height
Power Requirements
12V DC, 2.0A, 12V battery pack or adapter available
Power Supply
Universal AC/DC (supplied as standard)
Weight
2.0kgs
Dimensions
165×165×225mm³
Suggested Operating Range
4°C-45°C
Typical Measurement Range
0-15% Soot
Output Resolution 
0.0001
Analysis Time
Less than 30 seconds
Communication Port
RS232 port, 9-pin D-sub Female, PC compatible
Instrument Repeatability
0-3% soot ±0.1%, 3-15% soot ±0.3%
Non-volatile Memory Calibration
Factory: 0-10% soot
User: Up to 20 point curve fitting calibration, plus zero

  
Part Number
Descriptions
405-0011
InfraCal Soot Meter Plus, Model HATR-CP. Complete with HATR Sample Stage for direct measurement of suspended carbon (soot) level in diesel engine oils (factory calibrated to 10% soot concentration), Power Supply and Instruction Manual.
Accessories
403-0025 
Set of 6 Reference Oils in dropper bottles, appropriate for calibration and verification of reproducibility 0-12% soot range of Model HATR-CP and Model HATR-C. This set of reference oils has been correlated with the results obtained via thermal gravimetric analysis (TGA) of fresh used diesel oil samples.
403-0018 
InfraLog Serial Printer Prints calibration and measurement data, complete with sequence number, date and time. Includes all required cables.
403-0013 
Carrying Case with pre-diced pluck foam, 470×370×203mm³, 3.6kgs.
403-0003 
External 12V Battery Pack with 120V/60Hz charger (for use in North America). Includes carrying case with shoulder strap and cigarette lighter adapter cable for connection to analyzer. Provides 16 hours of continuous operation.
403-0002 
Cigarette Lighter Adapter Cable
403-0005 
Dust Cover
403-0001
Universal Switching Power Supply and Line Cord for use with InfraCal Analyzers. 90-264VAC, 50-60Hz input, regulated 12V/25W output
403-0014
Replacement Source/Cable Assembly
100-1005
InfraCal Soot Meter User's Manual
100-1011
InfraCal Soot Meter Plus User's Manual

  
Comparative Soot Measurements On Used Diesel Oil Samples
FT-IR, TGA, and InfraCal Soot Meter
Provided by Mobil Oil Company, Paulsboro Technical Center
Field Test Samples
Lab Engine Test Samples
Soot, % mass
Soot, % mass
Sample ID
FT-IR
TGA
Soot Meter 1
Soot Meter 2
Engine/Hours
TGA
Soot Meter 1
Soot Meter 2
A1
1.46
 
1.4 
1.4 
Mack T-8
 
 
 
B1
1.59
 
1.6 
1.6 
Hours:
0
0.13 
0.1 
0.0 
B2
1.82
 
1.8 
1.9 
 
50
1.76 
1.7 
1.7 
B3
1.94
 
1.9 
2.0 
 
100
3.13 
3.2 
3.1 
B4
2.56
 
2.5 
2.5 
 
150
4.48 
4.5 
4.4 
A2
2.74
2.65 
2.6 
2.6 
 
175
5.16 
5.0 
5.0 
B5
2.68
 
2.7 
2.7 
 
200
5.80 
5.8 
5.8 
B6
2.81
2.76 
2.8 
2.9 
 
225
6.38 
6.1 
6.0 
B7
2.82
2.90 
2.6 
2.7 
 
250
6.92 
6.1 
6.2 
B8
 
3.15 
3.0 
3.1 
DDC Series 60
 
 
 
B9
 
3.21 
3.2 
3.2 
Hours:
0
0.09 
0.0 
0.0 
B10
 
3.53 
3.3 
3.1 
 
24
0.83 
0.8 
0.8 
A3
 
3.54 
3.5 
3.6 
 
48
1.40 
1.4 
1.4 
A4
 
4.05 
4.0 
4.0 
 
72
1.98 
1.9 
1.9 
A5
 
4.40 
4.3 
4.4 
 
96
2.52 
2.5 
2.5 
A6
 
4.99 
4.5 
4.6 
 
120
3.05 
3.0 
2.9 
A7
 
6.12 
5.1 
5.1 
 
144
3.58 
3.5 
3.5 
A8
 
6.47 
5.7 
5.7 
 
168
4.10 
4.0 
4.1 
A9
 
7.00 
6.0 
6.1 
 
192
4.57 
4.5 
4.6 
 
 
 
 
 
 
216
5.03 
4.8 
4.9 
 
 
 
 
 
 
240
5.33 
5.0 
5.0 
Note: A & B series samples are different oil formulations.
Note: Soot Meter data was obtained using 2 production models. Each was calibrated to 5% soot, which accounts for measurement discrepancy in samples containing a higher percentage.

Wilks InfraCal Filtometer

 


供应美国Wilks公司的InfraCal Filtometer,是一种基于带通滤光片和热电式探测器技术的红外分析仪,可以提供高精度和高准确度的中红外定量分析测量。该系列InfraCal Filtometer具体如下特点:成本优势、便携性、检测速度快、无移动部件、环境影响小、适合于实验室或室外,应用范围广泛,包括:水或土壤中TOG/GPH、废水中的FOG、汽油中的乙醇和乙醇中的水、柴油发动机润滑油的烟尘、变压器油的抗氧化抑制剂、多层薄膜中的Nylon/EVA/EVOH、表面活性剂中的UM、金属零部件的清洗效率、D2O in H2O/H2O in D2O、金属基底的树脂涂料。

  
Principle
Fixed Wavelength Infrared Filtometer
Source
Pulsed Tungsten Lamp
Rated for 10,000 hours (2-5µm region) Pulsed IR Emitter (5-15µm region)
Detector
Fixed band pass filter/pyroelectric 
Wavelength(s) Selection
Dependent on Application - Most Infracal Filtometers use one analytical wavelength or one analytical and one reference. For non-standard Infracal Filtometers, wavelength(s) must be specified when ordering. 
Typical Measurement Time
Less than 30 seconds 
Measurement Range
Dependent on Infracal Filtometer/Sample Stage Selected
Reproducibility
±0.1% (at normal scale expansion) 
Dimensions
165×165×127mm³
Weight
2.0kg
Display
4 digit, 7-segment red LED, 5/8" character height
Power Requirements
Voltage-12VDC, +2% max. Power-7.5W max, 5Wtypical Input - Switchcraft 760 plug or equivalent, center positive 
Suggested Power Sources
Wall Supply, AC/DC converter type (supplied as standard) 12V auto battery adapter connector Portable 12V battery pack
Operating Temperature
4°C-45°C 
User Selected Calibration
Zero balance adjustment Up to 20 point curve fitting calibration 
Communications Port
RS232 port, 9-pin D-Sub female, PC compatible, for upload to PC, data logger or printer 
Part Number
 Descriptions
405-0006 
InfraCal Thickness Gauge, Model SR (Top Loader) Measures coating thickness on cut samples placed on the platform at the top of the InfraCal Filtometer. Power Supply and Instruction Manual included.
405-1004
InfraCal IR Card Reader Filtometer, Model CH-2. Complete with CH Sample Stage for use with standard film holder cards, 3.0µm filter/detector, Power Supply and Instruction Manual. Ideal for analysis of nylon film thickness.
405-0014 
InfraCal 1mm Cuvette Holder Analyzer, Model CVH-1 Complete with CVH-1 Sample Stage for use with 1mm Quartz Cuvette Cells, 3.4µm filter/detector Power Supply and Instruction Manual.
405-2015
InfraCal Card Reader Filtometer, Model CH-3. Complete with a Sealed Cell Holder Sample Stage, an application specified filter/detector, Power Supply and Instruction Manual (Does not include Sealed Cell).
405-2023
InfraCal Flow-Through Cuvette Cell Analyzer, Model FCC. For measuring antioxidants inhibitors in transformer oil.  Complete with mounted 2mm quartz cuvette flow-through cell, 2.76 micrometer analytical single wavelength filter/detector, Power Supply and Instruction Manual.
Sample Handling Accessories
403-0027
Set of 4-1 mm Quartz Cuvette Cells for use with CVH-1.
403-1022
FTIR Demountable Liquid Transmission Cell with CaF2 windows and 1000µm spacers. For use with Model CH-3
Accessories
403-1067
InfraLog Serial Printer, Model DT2205 Prints calibration and measurement data, complete with sequence number, date and time. Includes all required cables.
403-0013
Carrying Case for InfraCal Analyzers with pre-diced pluck foam. 470×370×203mm³, 3.6kgs.
403-0003
External 12V Battery Pack with 120v/60Hz charger (for use in North America). Includes carrying case with shoulder strap and cigarette lighter adapter cable for connection to analyzer. Provides 16 hours of continuous operation.
403-0002
Cigarette Lighter Adapter Cable

 

 

激光及光电器件产品目录  红外测距传感器/距离测量传感器
 

紫外发光二极管 
深紫外发光二极管 近紫外发光二极管
牙医蓝大功率发光二极管 大功率深紫外发光二极管 
发光二极管驱动  
激光二极管 
气体分析用激光二极管 超辐射激光二极管  
通用激光二极管  激光二极管驱动控制器  
光纤耦合激光二极管激光二极管配件
大功率泵浦激光二极管模块 半导体光学放大器 
红外发光二极管 
大功率红外发光二极管 中红外发光二极管 
发光二极管驱动 近红外发光二极管 
光电探测器 
热电堆探测器 硅光电探测器 
热释电探测器锗光电探测器 
中红外光电探测器InGaAs光电探测器 
紫外探测器  双波段探测器 

产品 
 

| 电感式近开关 |电容式接近开关 |安全开关| 漫反射光电传感器 | 背景消影型光电开关| 镜面反射 | 对射式光电开关 | 槽型光电开关 |光纤放大器 | 辨色传感器 | 模拟量激光测距传感器 | smartplug智能连接器 | 视觉传感器 | 超声波传感器 | 增量式编码器 | 绝对式编码器 | 线性编码器 |编码器附件 | 流动传感器 | 压力传感器 | 液位料位传感器 | 附件 

接近开关 更多 
电感式接近开关 防爆式,耐高温,超小型接近开关 
电容式接近开关 方形、圆柱型耐高温,料位开关 
磁性开关 方形、圆柱型 sine/cosine信号输出 


安全开关 更多 
独立型安全开关 外形小巧,全电子编码系统,可靠性非常高 
非独立型安全开关 非独立型安全开关必须和安全模块一起使用 


光电传感器 更多 
漫反射光电开关 外形尺寸小,还可以检测小物体,性价比高 
背景消影型光电开关 可以检测0.1mm厚度的物体,背景消影型 
镜面反射光电开关 检测距离长,最长达250m,开关频率高 
光纤和光纤放大器 多种规格的塑料和玻璃光纤,超小超精细的光纤 
对射式光电开关 检测距离长,有激光、红光等多种光源 
槽型光电传感器 开槽尺寸有多种可选 
视觉传感器 可以实现图像识别、纠偏等功能 
激光测距传感器 性价比高的激光测距,检测距离长10m 
辨色传感器 分辨双色、三色、多色等系列传感器 


超声波传感器 更多 
开关量输出 M18圆柱型、方形系列产品,有一个、两个开关量输出 
模拟量输出 M18、M30、方形系列产品,模拟量4~20mA输出 


编码器 更多 
绝对式编码器 单转,多转,最高达13位输出绝对式编码器 
增量式编码器 分辨率达到72000的高精度编码器 
线性编码器 分辨率达到0.1μm的高精度编码器 
编码器附件 包括电缆,联轴器,测量轮,适配器,电气模块等 


流动传感器 更多 
开关量输出 开关量PNP/NPN输出,用于检测管路气体液体 
模拟量输出 4...20mA,0...10V模拟量输出,检测管路液体气体 


压力传感器 更多 
开关量输出 开关量PNP、NPN输出,可检测管路气体、液体压力 
模拟量输出压力传感器 模拟量输出,陶瓷感应面,防护等级达到IP69 


液位料位传感器 更多 
电容型物位开关 有圆柱型、方型开关量输出系列产品 
音叉型物位开关 用于检测液位的一个位置点的专业产品 


附件 更多 
智能化接插件 可以实现计数、延时、PNP~NPN转换、测速等功能 
电缆线 M8 M12接插件 电缆线 ,耐高温、 耐油耐腐蚀 
流体传感器转接头 流量传感器、压力传感器转接头,耐高温、耐高压 


 

 德国原装进口新产品 
超远距离
激光测距传感器, 
检测长度达到250m
 
 德国生产的优质产品 
三通道颜色传感器
 
 美国bei编码器 
公司提供的用于 
防爆场合的
隔离模块
 
 德国原装进口产品 
带一个开关量输出,
带显示 流动开关
 
 美国BEI公司 
抗振编码器,可以提供 
增量式和绝对式输出
 
 德国原装进口新产品 
视觉传感器,可以用于 
检测零件缺陷,纠偏 
等工业场合
 
 美国BEI公司
线性编码器,可以提供
方波或正弦波输出
 
 原装进口
法国BTI安全开关
 
 

MTI(美国)
超高精度非接触量测系统

压电材料/薄膜/磁带振动测试、塑料基板厚度量测、传动组件(HDD)动态测试、轴承马达回转测试、IC脚位元间距、超音波溶接机/焊线机喷嘴振动测试、自动装配机械人……等,广泛运用于学术实验研究及工业自动化组件定位、品管检查等
●位移 ●厚度 ●振动 ●尺寸大小 ●平坦度 ●内外径 ●同轴度
 

MicrotrakII"高速"激光位移量测系统
分辨率:0.1um
取样频率:40kHz 
反应频率:20kHz(调整滤波功能可以达到0.1HZ)
不受表面物体材质、颜色及发射光源的影响
可视激光光点使激光头操作及对位更加容易
液晶荧幕公制/英制显示
菜单操作面板可设置上下限、补偿/增益范围、单位
可换激光头无需再校正
模拟输出和RS-485输出可连接其它计算机及资料采集系统
配套远程控制软件可以通过数据接口连接到电脑,实现波形显示及数据存储等功能
●特殊探头可以测量镜面型(光亮)表面 
 
超高精度激光量测系统MICROTRAK 7000
高分辨率:0.0025μm
取样频率:100kHz,反应频率:20kHz
液晶荧幕公制/英制显示
可见光激光光束,位置与量测点方便确认
功能健设定:上下限、归零、平均数……等功能
一台控制器可同时接二个激光头
可依需求换激光头无需再校正
模拟输出:电压(±10V)
数字接口:RS-232/IEEE-488即GPIB(可选)
设计客户专用OEM产品,配合使用者用途
●具有漫反射型及镜面光亮表面型 


 
光纤量测位移传感器MTI-2100 
超高分辨率:0.0025um
反应频率:190kHz(特殊探针到达500kHz)
数值显示面板
LCD液晶显示
可接二组传感器
可依据需求换探针无须再校正
最小探针外径0.17mm
输出:电压-10V to +10V
RS-232C数据接口
可定制弯曲探针及高温低温探针


 
非接触高精度静电容式量测系统
AS-1500(多频道型)

超高分辨率:纳米级
反应频率:5kHz
数值显示公制/英制、刻度频道显示
分段刻度频道显示
不受金属材质影响
可同时进行10个通道的测量
用于振动、位移、内外径量测,适于品管制造及学术实验




 
纳米级刹车盘测试系统AS-500
超高分辨率:纳米级 
反应频率:5kHz
用于刹车盘振动、厚度和DTV测量 
可同时进行6个通道测试 
可以有12VDC直流或交流供电 
能够安装标准或推拉式(PUSH-PULL)探头 
纳米级超高精度电容式传感器
AS-9000

超高分辨率:纳米级
反应频率:5kHz
价格经济、功能超强
能对极难检测的微小物体进行检测,且检测能力好上40倍
具有超高精度、稳定性、重复性和分辨率
被动式电容探头具有特别的温度稳定性
纳米级超高精度电容式传感器
AS-5000

超高分辨率:纳米级
反应频率:20kHz
价格经济、功能超强
能对极难检测的微小物体进行检测,且检测能力好上40倍
具有超高精度、稳定性、重复性和分辨率
被动式电容探头具有特别的温度稳定性
 
KD-300光纤位移传感器
分辨率:O.05μm
反应频率:70kHz
信号输出:0-10V dc,100欧姆
仪器工作温度:50F至150F(10摄氏度-65摄氏度)
测量不受磁场或静电影响,能对几乎所有非金属甚至漆黑表面的物体进行操作
探针长度:3in.(76.2mm)
电缆线长度:36in.(914 mm)
电源:小于3W,115/230V,50-400Hz
可定制弯曲探针 
 
 
MTI 其它传感器系列产品
●高频(20kHz)单、双、多频道(8CH)静电容量量测系统
●光纤偏缘量测与偏摆(Runout)量测系统
●非接触厚度量测系统