120
t
rr
, REVERSE RECOVERY TIME
(ns)
100
80
60
T
J
= 125°C
40
20
0
T
J
= 175°C
T
J
= 25°C
T
J
= -55°C
0.5
1
1.5
2
2.5
3
V
F
, ANODE-TO-CATHODE VOLTAGE (V)
Figure 25. Forward Current vs. Forward Voltage
1400
Q
rr
, REVERSE RECOVERY CHARGE
(nC)
1200
1000
800
600
400
200
0
T = 125°C
J
V = 400V
R
180
160
140
120
100
80
60
40
20
80A
APT30GT60BRDQ2(G)
T = 125°C
J
V = 400V
R
I
F
, FORWARD CURRENT
(A)
40A
20A
0
0
200
400
600
800 1000 1200
-di
F
/dt, CURRENT RATE OF CHANGE(A/µs)
Figure 26. Reverse Recovery Time vs. Current Rate of Change
I
RRM
, REVERSE RECOVERY CURRENT
(A)
25
T = 125°C
J
V = 400V
R
0
80A
80A
20
15
40A
10
40A
20A
20A
5
0
200
400
600
800 1000 1200
-di
F
/dt, CURRENT RATE OF CHANGE (A/µs)
Figure 27. Reverse Recovery Charge vs. Current Rate of Change
0
200
400
600
800 1000 1200
-di
F
/dt, CURRENT RATE OF CHANGE (A/µs)
Figure 28. Reverse Recovery Current vs. Current Rate of Change
80
Duty cycle = 0.5
T = 175°C
J
0
1.4
K
f
, DYNAMIC PARAMETERS
(Normalized to 1000A/µs)
1.2
1.0
0.8
0.6
0.4
0.2
t
rr
Q
rr
I
RRM
70
60
I
F(AV)
(A)
50
40
30
t
rr
Q
rr
20
10
25
50
75
100
125
150
T
J
, JUNCTION TEMPERATURE (°C)
Figure 29. Dynamic Parameters vs. Junction Temperature
0.0
0
75
100
125
150
175
Case Temperature (°C)
Figure 30. Maximum Average Forward Current vs. CaseTemperature
0
25
50
200
C
J
, JUNCTION CAPACITANCE
(pF)
180
160
140
120
100
80
60
40
20
10
100 200
V
R
, REVERSE VOLTAGE (V)
Figure 31. Junction Capacitance vs. Reverse Voltage
Rev A
12-2005
0
1
052-6282