A617308 Series
Recommended DC Operating Conditions
(TA = 0°C to + 70°C)
Symbol
VCC
GND
VIH
Parameter
Supply Voltage
Ground
Min.
4.5
0
Typ.
Max.
5.5
0
Unit
V
5.0
0
V
Input High Voltage
Input Low (1) Voltage
Output Load
2.2
-0.5
-
-
VCC + 0.5
+0.8
V
V
VIL
0
CL
-
30
pF
Absolute Maximum Ratings*
*Comments
VCC to GND . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to +7V
IN, IN/OUT Volt to GND . . . . . . . . . . -0.5V to VCC +0.5V
Operating Temperature, Topr . . . . . . . . . . . 0°C to +70°C
Storage Temperature, Tstg . . . . . . . . . . -55°C to +125°C
Temperature Under Bias, Tbias . . . . . . . . -10°C to +85°C
Power Dissipation, PT . . . . . . . . . . . . . . . . . . . . . . . 1.0W
Stresses above those listed under "Absolute Maximum
Ratings" may cause permanent damage to this device.
These are stress ratings only. Functional operation of this
device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied or intended. Exposure to the absolute maximum
rating conditions for extended periods may affect device
reliability.
DC Electrical Characteristics (TA = 0°C to + 70°C, VCC = 5V ± 10%, GND = 0V)
A617308-10/12/15
Symbol
Parameter
Unit
Conditions
Min.
Max.
Input Leakage
-
5
VIN = GND to VCC
½ILI½
mA
mA
CE1 = VIH, CE2= VIL or OE = VIH
VI/O = GND to VCC
Output Leakage
-
5
½ILO½
= VIL, CE2 = VIH , II/O = 0 mA
Min. Cycle, Duty = 100%
CE1
ICC1 (2)
ISB
Dynamic Operating Current
-
-
150
35
mA
mA
= VIH or CE2 = VIL
CE1
Standby Power
Supply Current
CE1 ³ VCC - 0.2V, CE2 £ 0.2V
VIN ³ VCC -0.2V or VIN £ 0.2V
ISB1
-
12
mA
VOL
VOH
Output Low Voltage
Output High Voltage
-
0.4
-
V
V
IOL = 8 mA
2.4
IOH = -4 mA
Notes: 1. VIL = -3.0V for pulses less than 20 ns.
2. ICC1 is dependent on output loading, cycle rates, and Read/Write patterns.
PRELIMINARY
(January, 2000, Version 0.2)
3
AMIC Technology, Inc.