欢迎访问ic37.com |
会员登录 免费注册
发布采购

MC68HC908AS60CFU 参数 Datasheet PDF下载

MC68HC908AS60CFU图片预览
型号: MC68HC908AS60CFU
PDF下载: 下载PDF文件 查看货源
内容描述: HCMOS微控制器单元 [HCMOS Microcontroller Unit]
分类和应用: 微控制器外围集成电路时钟
文件页数/大小: 454 页 / 5714 K
品牌: FREESCALE [ FREESCALE SEMICONDUCTOR, INC ]
 浏览型号MC68HC908AS60CFU的Datasheet PDF文件第138页浏览型号MC68HC908AS60CFU的Datasheet PDF文件第139页浏览型号MC68HC908AS60CFU的Datasheet PDF文件第140页浏览型号MC68HC908AS60CFU的Datasheet PDF文件第141页浏览型号MC68HC908AS60CFU的Datasheet PDF文件第143页浏览型号MC68HC908AS60CFU的Datasheet PDF文件第144页浏览型号MC68HC908AS60CFU的Datasheet PDF文件第145页浏览型号MC68HC908AS60CFU的Datasheet PDF文件第146页  
Freescale Semiconductor, Inc.
System Integration Module (SIM)
indexed addressing and PUL/PSH instructions will also generate an
illegal address reset.
WARNING:
Extra care should be exercised when using this emulator part for
development of code to be run in ROM-based M68HC08AS Family
parts with a smaller memory size since some legal addresses will
become illegal addresses on the smaller ROM memory map device
and may, as a result, generate unwanted resets.
Freescale Semiconductor, Inc...
9.4.2.5 Low-Voltage Inhibit (LVI) Reset
The low-voltage inhibit (LVI) module asserts its output to the SIM when
the V
DD
voltage falls to the V
LVII
voltage. The LVI bit in the SIM reset
status register (SRSR) is set and a chip reset is asserted if the LVIPWRD
and LVIRSTD bits in the CONFIG-1 register are at logic 0. The RST pin
will be held low until the SIM counts 4096 CGMXCLK cycles after V
DD
rises above V
LVIR
. Another 64 CGMXCLK cycles later, the CPU is
released from reset to allow the reset vector sequence to occur.
See
9.5 SIM Counter
The SIM counter is used by the power-on reset module (POR) and in
stop mode recovery to allow the oscillator time to stabilize before
enabling the internal bus (IBUS) clocks. The SIM counter also serves as
a prescaler for the computer operating properly module (COP). The SIM
counter overflow supplies the clock for the COP module. The SIM
counter is 12 bits long and is clocked by the falling edge of CGMXCLK.
9.5.1 SIM Counter During Power-On Reset
The POR detects power applied to the MCU. At power-on, the POR
circuit asserts the signal PORRST. Once the SIM is initialized, it enables
the clock generation module (CGM) to drive the bus clock state machine.
Technical Data
System Integration Module (SIM)
For More Information On This Product,
Go to: www.freescale.com
MC68HC908AS60 — Rev. 1.0