Specifications
ispLSI and pLSI 1032
Absolute Maximum Ratings
1
Supply Voltage V
cc
...................................-0.5 to +7.0V
Input Voltage Applied ........................ -2.5 to V
CC
+1.0V
Off-State Output Voltage Applied ..... -2.5 to V
CC
+1.0V
Storage Temperature ................................ -65 to 150°C
Case Temp. with Power Applied .............. -55 to 125°C
Max. Junction Temp. (T
J
) with Power Applied ... 150°C
1. Stresses above those listed under the “Absolute Maximum Ratings” may cause permanent damage to the device. Functional
operation of the device at these or at any other conditions above those indicated in the operational sections of this specifica tion
is not implied (while programming, follow the programming specifications).
DC Recommended Operating Conditions
SYMBOL
PARAMETER
Commercial
T
A
= 0°C to +70°C
T
A
= -40°C to +85°C
T
C
= -55°C to +125°C
MIN.
4.75
4.5
4.5
0
2.0
MAX.
5.25
5.5
5.5
0.8
Vcc
+ 1
V
V
Table 2- 0005Aisp w/mil.eps
UNITS
V
CC
V
IL
V
IH
Supply Voltage
Industrial
Military/883
V
Input Low Voltage
Input High Voltage
Capacitance (T
A
=25
o
C, f=1.0 MHz)
SYMBOL
PARAMETER
Dedicated Input Capacitance
I/O and Clock Capacitance
Commercial/Industrial
Military
MAXIMUM
1
8
10
10
UNITS
pf
pf
pf
TEST CONDITIONS
V
CC
=5.0V, V
IN
=2.0V
V
CC
=5.0V, V
IN
=2.0V
V
CC
=5.0V, V
I/O
, V
Y
=2.0V
Table 2- 0006
C
1
C
2
1
.
Guaranteed but not 100% tested.
Data Retention Specifications
PARAMETER
Data Retention
ispLSI Erase/Reprogram Cycles
pLSI Erase/Reprogram Cycles
MINIMUM
20
10000
100
MAXIMUM
–
–
–
UNITS
Years
Cycles
Cycles
Table 2- 0008B
3
1996 ISP Encyclopedia