128Mb, 256Mb, 512Mb, 1Gb StrataFlash Memory
Dual Operation
Dual Operation
Multipartition architecture of the device enables reading from one partition while a
PROGRAM or ERASE operation is occurring in another partition. This is called read-
while-program and read-while-erase, respectively.
Only status reads are allowed from a partition that is busy programming or erasing. If
non-status reads are required from a partition that is busy programming or erasing, the
PROGRAM or ERASE operation must be suspended first.
Table 30: Dual Operation Restrictions
The following table shows the allowed dual operations between array operations and non-array operations
Program or Erase
Read
Program OTP Area
Main Partition
Main Partition
Status
ID, OTP, or CFI
Yes (except busy partition)
Yes
Yes (except busy partition)
Yes (except busy partition)
Yes
No