256Mb and 512Mb (256Mb/256Mb), P30-65nm
Program Operations
Program Resume
The RESUME command instructs the device to continue programming, and automati-
cally clears SR[7,2]. This command can be written to any address. If error bits are set,
the status register should be cleared before issuing the next command. RST# must re-
main de-asserted.
Program Protection
When V
PP
= V
IL
, absolute hardware write protection is provided for all device blocks. If
V
PP
is at or below V
PPLK
, programming operations halt and SR3 is set, indicating a V
PP
-
level error. Block lock registers are not affected by the voltage level on V
PP
; they may still
be programmed and read, even if V
PP
is less than V
PPLK
.
Figure 11: Example V
PP
Supply Connections
V
CC
V
PP
< 10K
Ω
V
CC
V
PP
V
CC
PROT#
V
CC
V
PP
-Factory programming with V
PP
= V
PPH
-Complete with program/erase
protection when V
PP
< V
PPLK
-Low voltage programming only
-Logic control of device protection
V
CC
V
PP
=
V
PPH
V
CC
V
PP
V
CC
V
CC
V
PP
-Low voltage and factory programming
-Low voltage programming only
-Full device protection unavailable
PDF: 09005aef84566799
p30_65nm_MLC_256Mb-512mb.pdf - Rev. C 12/13 EN
38
Micron Technology, Inc. reserves the right to change products or specifications without notice.
©
2013 Micron Technology, Inc. All rights reserved.