OKX
T/10 & T/16-D12 Series
Adjustable DOSA 10/16-Amp SIP DC/DC Converters
Performance Specifications and Ordering Guide
ORDERING GUIDE
Output
Input
Iin,
no load
(mA)
80
Iin,
full load
(Amps)
4.41
Efficiency
Min.
93%
Typ.
94.5%
Pos.
Neg.
Pos.
Neg
Pos.
Neg.
Pos.
Neg.
no
no
yes
yes
no
no
yes
yes
On/Off Sequence/
Polarity Track
Package C83,
Pinout P83
Case
Dimensions are
in inches (mm)
Model Number
➁
OKX-T/10-D12P-C
V
OUT
(Volts)
0.75-5.5
Regulation (Max.)
I
OUT
R/N
(Amps Power
(mVp-p)
Vin Nom. Range
max) (Watts)
Max.
Line
Load
(Volts) (Volts)
➀
10
50
40
±0.15% ±0.25%
12
8.3-14
2.0x0.5x0.37
(50.8x12.7x9.4)
2.0x0.5x0.37
(50.8x12.7x9.4)
2.0x0.5x0.37
(50.8x12.7x9.4)
2.0x0.5x0.37
(50.8x12.7x9.4)
2.0x0.5x0.37
(50.8x12.7x9.4)
2.0x0.5x0.37
(50.8x12.7x9.4)
2.0x0.5x0.37
(50.8x12.7x9.4)
2.0x0.5x0.37
(50.8x12.7x9.4)
OKX-T/10-D12N-C
0.75-5.5
10
50
40
±0.15% ±0.25%
12
8.3-14
80
4.41
93%
94.5%
OKX2-T/10-D12P-C
0.75-5.5
10
50
40
±0.15% ±0.25%
12
8.3-14
80
4.41
93%
94.5%
OKX2-T/10-D12N-C
0.75-5.5
10
50
40
±0.15% ±0.25%
12
8.3-14
80
4.41
93%
94.5%
OKX-T/16-D12P-C
0.75-5.5
16
80
40
±0.15% ±0.25%
12
8.3-14
80
7.09
92.5%
94%
OKX-T/16-D12N-C
0.75-5.5
16
80
40
±0.15% ±0.25%
12
8.3-14
80
7.09
92.5%
94%
OKX2-T/16-D12P-C
0.75-5.5
16
80
40
±0.15% ±0.25%
12
8.3-14
80
7.09
92.5%
94%
OKX2-T/16-D12N-C
➀
②
0.75-5.5
16
80
40
±0.15% ±0.25%
12
8.3-14
③
④
80
7.09
92.5%
94%
The input voltage range must be 13.2 Volts max. for Vout >= 3.63 V.
All specifications are at nominal line voltage, Vout=nominal (5V for D12 models) and full load, +25 deg.C. unless
otherwise noted.
Output capacitors are 1 μF ceramic and 10 μF electrolytic in parallel. Input cap is 22 μF. See detailed specifications.
I/O caps are necessary for our test equipment and may not be needed for your application.
Use adequate ground plane and copper thickness adjacent to the converter.
Ripple and Noise (R/N) is shown at Vout=1V. See specs for details.
PART NUMBER STRUCTURE
OKX 2
-
T
/
16
-
D12 P
-
C
Output
Configuration:
Adjustable output, unipolar,
non-isolated, low voltage,
single inline package (SIP)
Sequence/tracking
Blank = Not installed, delete pin 9
2 = Installed, add pin 9
Trimmable Output
Voltage Range
D12 Models = 0.75-5.5V
Maximum Rated Output
Current in Amps
RoHS Hazardous
Substance Compliance
C
= RoHS6 (does
not claim EU RoHS
exemption 7b–lead in solder)
On/Off Polarity
P = Positive Polarity
N = Negative Polarity
Input Voltage Range
D12 = 8.3-14V
Note:
Some model number combinations
may not be available. See Ordering Guide
above. Contact Murata Power Solutions for
availability.
www.murata-ps.com
Technical enquiries
email: sales@murata-ps.com, tel:
+1 508 339 3000
MDC_MDC_OKX2_T10T16.A03
Page 2 of 15